Acid Vapour Collecting Room
Parameter and Specification
* All the pretreatment tanks are installed inside pits which is higher than ground. The operators will walk on the pass way which is higher than ground.
* The working surrounding of operators are very safe.
* The round roof of PPH boards are installed on brim of all tanks. All the liquid drops from tank to tank will go back acid tank.
* The principle of collecting and exhausting acid vapour is to keep tank surface little negative pressure.
Collection device number |
1 |
Acid tank number |
6 |
Acid vapour exhausting device number |
1 |
Scrubbing tower |
1 |
Exhausting capacity |
50m3/h |
Flue size |
Diameter 1.2m x length 6.5m |
Scrubbing tower size |
Diameter 2.1m x height 8.0m |
Washing medium |
Recycle water |
Washing water discharge |
Use for add water for acid washing tank |
PH value indicator |
Has |
Washing efficiency |
HCI<5ppm |
PRODUCTION LINE INFO.
- Treatment Tank
- Heating Device
- Energy Saving Heat Exchanger
- Acid Vapour Collecting Room
- Drying Furnace
- Galvanizing Furnace and Zine Bath
- White fume suction hood
- White fume exhauster and filter
- Furnace Cover and Platform
Other CLIMA Production Line
- CLIMA Homepage
- Hot dip wire galvanizing production line
- Steel palnt
- Longitudinal Welding Pipe Production Line
- Steel Drum Production Line
- Steel tower
- Welding pipe production line
- Nail Making Machine
- Ceramic tile making machine
- prefabricated house
- aluminium tube production line
- railway wagon & railway wagon fittings